Polyurethane sealant testing report

The polyurethane sealant testing report is the core document for evaluating product quality and ensuring compliance with engineering standards, usually issued by third-party organizations with CMA/CNAS qualifications. The report revolves around core indicators such as appearance, construction, mechanics, and durability. The following is a complete analysis and standard template.
1、 Report Core Information (Header)
Report Number: (Unique Identification Code)
Sample name: Single/two-component polyurethane sealant
Model specifications: high modulus/low modulus, grade 25/20
Production unit: XXX Company
Client: XXX Company
Testing basis:
JC/T 482-2022 “Polyurethane Building Sealant” (current national standard)
GB/T 13477 “Test Methods for Building Sealing Materials” series
Testing date: XX/XX/XXXX – XX/XX/XXXX
Detection environment: temperature (23 ± 2) ℃, humidity (50 ± 5)%
2、 Core Testing Items and Qualification Standards (JC/T 482-2022)

  1. Appearance quality
    Requirements: fine and even paste, no bubble, no caking, no gel
    Judgment: Qualified/Unqualified
  2. Construction performance
    table
    Testing project technical requirements (standards) qualification judgment
    Density (g/cm ³) specified value ± 0.1 qualified
    Squeezing ability (mL/min) ≥ 80 (easy to construct) qualified
    Dry time (h) ≤ 24, qualified
    Sag (mm) ≤ 3 (no sagging during vertical construction) Qualified
    Low temperature flexibility (℃) ≤ -40 (no cracks) qualified
  3. Mechanical bonding performance (core)
    table
    Test item 25 (high modulus) and 20 (medium modulus) qualified judgment
    Tensile bonding strength (MPa) ≥ 0.5 ≥ 0.4, qualified
    Tensile elongation at break (%) ≥ 1000 ≥ 800, qualified
    Elastic recovery rate (%) ≥ 90 ≥ 85, qualified
    No damage to the adhesive properties of the fixed extension, no detachment, no damage, and no detachment are qualified
    After immersion in water, the adhesion of the fixed extension is not damaged, there is no detachment, no damage, and no detachment is qualified
  4. Durability and aging performance
    table
    Testing project technical requirements qualification judgment
    Thermal aging (70 ℃/28d) with a quality loss of ≤ 5% is qualified
    UV aging without cracks, no powdering qualified
    Water absorption rate (%) ≤ 3, qualified
  5. Environmental performance (optional)
    VOC content: compliant with GB 18583 standard
    Mold proof grade: Level 0 (highest grade)